2U Rack Design
Rack-mounted installation across the 1–3kVA range.
C Rack Series
2U rack-mounted UPS with pure sine wave output and an LCD status display.

Rack-mounted installation across the 1–3kVA range.
Rated output power of 1kW, 2kW or 3kW.
Pure sine wave output for connected equipment.
Multifunction LCD status display and control panel.
Standard and external lead-acid battery configurations.
1–8A for standard UPS; 1–12A for external battery UPS.
The C Rack Series includes C1KR, C2KR and C3KR standard models, plus external battery versions with an S suffix. Each model uses a 2U rack-mounted chassis and provides pure sine wave output with an output power factor of 1.
Compare all three capacities below. Standard and external battery versions have separate battery and physical specifications.
Compare all C Rack Series models at a glance.
Swipe horizontally to compare all models.
| Parameter | C1KR | C2KR | C3KR |
|---|---|---|---|
| General | |||
| Rated capacity / power | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW |
| Installation | Rack-mount | ||
| Input | |||
| Nominal input voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||
| Input frequency | 44–56 Hz or 54–66 Hz (default) | ||
| Input power factor | ≥0.999 | ||
| Wiring | L+N+PE | ||
| Input voltage range (200–240V models) | 110–300 VAC; power derating at 110–176 VAC and 280–300 VAC | ||
| Output | |||
| Output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||
| Voltage regulation (battery mode) | ±1% | ||
| Frequency synchronization range | 44–56 Hz or 54–66 Hz (default) | ||
| Output power factor | 1 | ||
| Harmonic distortion | ≤3% THD (linear load); ≤6% THD (nonlinear load) | ||
| Transfer time | 0 | ||
| Waveform | Pure sine wave | ||
| Overload capacity (line mode) | 30 min at 102–110%; 10 min at 110–130%; 30 s at 130–150%; 200 ms at >150% | ||
| Overload capacity (battery mode) | 1 min at 102–110%; 10 s at 110–130%; 3 s at 130–150%; 200 ms at >150% | ||
| Battery | |||
| Battery type | Lead-acid VRLA | ||
| Charging current | 1–8 A (adjustable) | ||
| Battery voltage | 24VDC | 48VDC | 48/72VDC |
| Battery capacity options | 12V7Ah/9Ah × 2 | 12V7Ah/9Ah × 4 | 48V: 12V 7Ah/9Ah × 4; 72V: 12V 7Ah/9Ah × 6 |
| Efficiency | |||
| Mains power mode | 94.5% | 95.5% | |
| Battery mode | 87.5% | 89.5% | 91.5% |
| Communication | |||
| Control panel | Multifunction LCD status display and control panel | ||
| Standard interfaces | RS232 / USB | ||
| Optional interfaces | AS400 / RS485 / SNMP | ||
| Environment | |||
| Operating humidity | 20–95% RH (non-condensing) | ||
| Noise at full load (1 m) | <50 dBA at 1 m | ||
| Operating temperature | −25–55°C | ||
| Physical | |||
| Dimensions (L × W × H) | 380 × 438 × 88[2U] mm | 48V: 380 × 438 × 88 mm (2U); 72V: 520 × 438 × 88 mm (2U) | |
| Net weight | 10.8 kg | 14.6 kg | 48V: 14.8 kg; 72V: 20 kg |
Swipe horizontally to compare all models.
| Parameter | C1KRS | C2KRS | C3KRS |
|---|---|---|---|
| General | |||
| Rated capacity / power | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW |
| Installation | Rack-mount | ||
| Input | |||
| Nominal input voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||
| Input frequency | 44–56 Hz or 54–66 Hz (default) | ||
| Input power factor | ≥0.999 | ||
| Wiring | L+N+PE | ||
| Input voltage range (200–240V models) | 110–300 VAC; power derating at 110–176 VAC and 280–300 VAC | ||
| Output | |||
| Output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||
| Voltage regulation (battery mode) | ±1% | ||
| Frequency synchronization range | 44–56 Hz or 54–66 Hz (default) | ||
| Output power factor | 1 | ||
| Harmonic distortion | ≤3% THD (linear load); ≤6% THD (nonlinear load) | ||
| Transfer time | 0 | ||
| Waveform | Pure sine wave | ||
| Overload capacity (line mode) | 30 min at 102–110%; 10 min at 110–130%; 30 s at 130–150%; 200 ms at >150% | ||
| Overload capacity (battery mode) | 1 min at 102–110%; 10 s at 110–130%; 3 s at 130–150%; 200 ms at >150% | ||
| Battery | |||
| Battery type | Lead-acid VRLA | ||
| Charging current | 1–12 A (adjustable) | ||
| Battery voltage | 36VDC | 72VDC | 96VDC |
| Efficiency | |||
| Mains power mode | 94.5% | 95.5% | |
| Battery mode | 87.5% | 89.5% | 91.5% |
| Communication | |||
| Control panel | Multifunction LCD status display and control panel | ||
| Standard interfaces | RS232 / USB | ||
| Optional interfaces | AS400 / RS485 / SNMP | ||
| Environment | |||
| Operating humidity | 20–95% RH (non-condensing) | ||
| Noise at full load (1 m) | <50 dBA at 1 m | ||
| Operating temperature | −25–55°C | ||
| Physical | |||
| Dimensions (L × W × H) | 380 × 438 × 88[2U] mm | ||
| Net weight | 5.45 kg | 6.55 kg | 6.75 kg |
Tell us your requirements and our team will help identify a suitable C Rack Series UPS solution for your application.